Roof Ventilators -
Roofing, Siding & Trims
Wall Louvres
EV-WL
• Complete with screen
• Custom sizes available
• Special order
Round Ventilators
EV-Round
• Available in 12” throat size
• Use 1-12” vent per 390 sq. ft.
• Special order
Ridgilators
EV-4
• Use 1 ridgilator per 560 sq. ft. of attic area
• EV-4DK - Deflector Kit (Also Shown)
• Recommended for use with ridgilator on 6/12 pitch or more
48” Low Profile Ventilators
EV-3
• Use 1 low profile vent per 1170 sq. ft. of attic area
Enviro-Vent
EV-2
• For use at ridge and hip
• Conforms to G-Rib Profiles
• Fast, easy and economical to install in 36” lengths
Ridge Vent
EV-5
• For use at ridge, hip and side wall
• Conforms to Canadian building codes
• Available in8”x20’ roll
• Use in conjunction with caulking on steel roofs
Easy Super Soffit
EV-1
• No extra screening required
• Good looking solution to soffit air intake - No unslightly big holes
• For every 10’ of building width your
attic requires 1” of continuous super soffit
per eave. Eg. 40’ wide building requires
4” continuous super soffit at each eave.
- Print Brochure